- It allows to manage ventilation, heating, cooling, alarm, timing, weather station, ventilation stages, statistics, curves and air-inlet.
- Control of the equipment with colour touch screen.
- Independent control of each one of the 4 group of air-inlets.
- It can drive directly single-phase and three phases motor-gears. Maximum power:
· Single phase motor - gear 2,2 Kw
· Three phase motor gear 4 Kw
- It has 4 stages to control directly the motor-gears in order to manage the air-inlets and the curtains.
- Environmental control of the farm.
- Digital inputs for counters (water, grain, etc).
- 0-10 V outputs to control a power stage, a frequency adjuster or additional air-inlets control stage.
- It manages up to 12 ventilation stages.
- The ventilation, heating, cooling and thermal contact can be time modulated.
- It has programmable temperature curves.
- Statistics function for total control of the farm.
- Maximum and minimum temperature alarm.
- Configurable relays for ventilation, heating, cooling and humidity.
- A weather station can be connected.
- Built-in communications: CTINET total control system of the farm through:
· Central computer in the farm (radio/wire).
· External computer or smartphone (internet).