Designed to comply with the international standard ISO / EN 13849. It consists of a main CPU for running the user application and a smaller diagnostic CPU, which continuously monitors the main CPU and safety-critical inputs and outputs.
+ Safe
+ Flexible
+ Multifunctional
In the event that an error is detected, an internal switch opens, disconnecting all output stages from power and moving the vehicle to a safe state.
These safety features prevent uncontrolled vehicle and equipment movements, thus ensuring safe working conditions for users. HY-TTC 94 meets PL d (Performance Level d) requirements.